To learn more about the software which generates this data, please visit Bill, K8CU at:

www.realhamradio.com

NavSymm Proteus

Symmetricom UCCM 1

Symmetricom UCCM 2

Local weather.

Z3801A power-on time
Days Hrs Mins Secs
Since 18 July 2003
                                  +0,"No error"                                 
Life     +63824                               EFC     +899666
SYNCHRONIZATION ............................................. [ Outputs Valid ]
SmartClock Mode ___________________________   Reference Outputs _______________
>> Locked to GPS                              TFOM     3             FFOM     0
   Recovery                                   1PPS TI +8.9 ns relative to GPS
   Holdover                                   HOLD THR 1.000 us
   Power-up                                   Holdover Uncertainty ____________
                                              Predict  3.6 us/initial 24 hrs
                                                
ACQUISITION ............................................ [ GPS 1PPS CLK Valid ]
Satellite Status __________________________   Time _____ Leap seconds 18 ______
Tracking: 6        Not Tracking: 4            UTC      15:54:54     04 Oct 2021
PRN  El  Az   SS   PRN  El  Az                1PPS CLK Synchronized to UTC
  5  61 278  130     2  11 216                ANT DLY  25 ns
  7  45  62   94     9  11  92                Position ________________________
 13  45 269  133    15  16 277                MODE     Hold
 14  18 144   64    18  13 328                
 20  61 199   87                              LAT      N  53:00:30.905
 30  72 116  148                              LON      W   1:12:00.548
ELEV MASK 10 deg                              HGT               +67.84 m  (MSL)
HEALTH MONITOR ...................................................... [ ERROR ]
Self Test: Err   Int Pwr: OK   Oven Pwr: OK   OCXO: OK   EFC: OK   GPS Rcv: OK